Application
Furnace Control Board
Control Voltage
24 VAC (18-30 VAC)
Line Voltage
120 VAC
Operating temperature
-40°to 175°F (-40°to 80°C)
HSI Hot Surface Ignitor
6 amp @ 120 VAC
Gas Valve
1.5 amp @ 24 VAC
Inducer draft motor
2.2 FLA @120 VAC
Blower motor
14.5 FLA @ 120 VAC
Operating Temp Range
-40° to 176°F (-40° to 80°C)
Humidity Range
5 to 95% relative humidity (non-condensing)
WEIGHT/DIMENSIONS
Weight: 1 lb., Length: 5.125, Width: 7.0, Height: 1.25
Brands Supported
Universal
Item Shipping Weight (lbs.)
1.00
- Controls Gas Valve, Igniter, Blower Motor, Inducer, Humidifier and Air Cleaner
- Microprocessor Based Precision
- Software for Enhanced Controls Operation in Counterflow and Downflow Furnace Application
- Designed for 100 Percent Gas Shutoff in Case of Ignition Failure
- Twinning Compatible with an other ICM282A Control
- Reverse Polarity Protection
- Secondary Brownout Voltage Protection
- Compatible with 24 Volt AC Standard Thermostat
- Provide Diagnostic LED to Aid in Troubleshooting