Application
Intermittent Pilot Ignition Control
Ignition Type
Intermittent Pilot
Ignition Between Trail Time
5 minute delay after failed trial for ignition.
Ignition Sequence
Continuous Retry
Ignitor Electrical Rating
24 V AC
Ignition Trials To Lockout
Continuous Retry
Pre-Purge
Configurable to 30 sec or no prepurge
Lockout Timing
Continuous Retry
Flame Failure Response Time
2 seconds maximum
Thermostat Anticipator Rating
0.2 A plus pilot valve rating plus main valve rating
Frequency
60 Hz
Operating Voltage
24 V AC
Includes
Spark cable adapters to allow field replacement of both Honeywell Home and competitive controls without replacing existing spark cable
Brands Supported
Universal
- Universal Intermittent Pilot Ignition Module Replaces Multiple Field Installed Intermittent Pilot Modules
- Uses Existing Intermittent Pilot Burner
- Provides Ignition Sequencing, Flame Monitoring and Safety Shut-Off for Intermittent Pilot Warm Air Furnaces and Heating Appliances
- Provides 100 Percent Pilot Gas Shut-Off if Pilot Fails to Light
- After 6 Minute Delay, Trial for Ignition is Repeated
- Ignition Trial/Delay Sequence is Repeated Until the Appliance Lights or Call for Heat is Removed